| ** Model MV-30 does not have an internal bypass because of space restrictions within the unit. Consequently, the Model MV-30 requires an external bypass and low-flow flowmeter in order to meet the water flow requirements. |
| AVAILABLE OPTIONS | Warranty |
pool/spa combination |
TECHNICAL SPECIFICATIONS |
Model MV-30 |
Model MV-70 |
Model MV-100 |
| BTU OUTPUT/HR. AT 80o F water/80% RH/80o F air | 30,000 |
70,000 |
100,000 |
| COEFFICIENT OF PERFORMANCE (COP) | 5.46 |
5.10 |
6.10 |
| KW Input | 1.6 |
4.4 |
4.8 |
| COMPRESSOR TYPE | Reciprocating |
Reciprocating |
Scroll |
| ELECTRICAL | 220 Volts, 60 HZ, Single Phase | ||
| MINIMUM AMPACITY (AMPS) | 11 |
25.4 |
37.3 |
| MAXIMUM BREAKER SIZE (AMPS) | 20 |
45 |
60 |
| AIR FLOW (CFM) | 3,000 |
4,000 |
4,000 |
| WATER FLOW (GPM) | 4-5 |
15-60 |
15-60 |
| WEIGHT (lbs) | 135 |
220 |
245 |
| LENGTH (ins) | 35 |
37 |
37 |
| WIDTH (ins) | 23 |
27 |
27 |
| DEPTH (ins) | 17 |
25 |
27 |